Just as rod seals are designed to keep fluid in, wipers perform to keep contamination out. Wipers
work in conjunction with rod seals to form the first line of defense in protecting a system and
keeping it free from dirt, mud, water, and other contaminants.
Click each link below to expand the corresponding Product Information.
- YD Profile, Premium Snap-in Wiper with O.D. Exclusion Technology
The YD wiper is the premier design among high performance, snapin excluders. Featuring a secondary
O.D. lip which seals against the shoulder region of the gland, the YD prevents water and other
contaminants from entering around the static side of the wiper. For ultimate performance, the YD also
incorporates an aggressive, knife-trimmed wiping lip to ensure maximum exclusion along the rod. A true
zero-radius lip provides the most effective wiping action available.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4300A90 |
-65°F to 275°F (-54°C to 135°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- SHD Profile, Industrial Snap-In Wiper
Parker SHD wipers are an outstanding choice for light and medium duty hydraulic and pneumatic
applications. The slotted heel design prevents pressure traps from forming between the rod seal and
wiper. Broad tooling availability, up to 30", makes the SHD a good choice for large rod diameters. The
snap-in design is oversized for a snug fit and excellent stability. This makes the SHD a great all-round
wiper in an economical package.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4615A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
P5065A88 |
-70°F to 200°F (-57°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
N4263A90 |
-20°F to 275°F (-29°C to 135°C) |
< 3.3 ft/s (1.0 m/s) |
V4208A90 |
-5°F to 400°F (-21°C to 204°C) |
< 3.3 ft/s (1.0 m/s) |
E4207A90 |
-65°F to 300°F (-54°C to 149°C) |
< 3.3 ft/s (1.0 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- SHX Profile, Performance Snap-In Wiper with O.D. exclusion technology
Parker SHX wipers offer an improvement over standard D-style wipers by adding O.D. exclusion
technology that prevents water and other contamination from entering the system from the static side of
the groove. This profile is ideal for applications where the rod is positioned vertically and could allow
moisture to collect in the wiper gland. SHX wipers retrofit industry standard D wiper grooves, making the
upgrade process simple and economical.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4615A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
P5065A88 |
-70°F to 200°F (-57°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- SH959 Profile, AN-Style Snap-In Wiper
Parker SH959 wipers are AN style excluders designed to ensure proper fit with all MS-28776 (MS-33675)
dash size grooves. The slotted heel design prevents pressure traps from forming between the rod
seal and wiper. This profile of wiper requires very little radial or axial space. This is why they are ideal in
light to medium duty hydraulic and pneumatic applications where such space constraints are present.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4615A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
P5065A88 |
-70°F to 200°F (-57°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
N4263A90 |
-20°F to 275°F (-29°C to 135°C) |
< 3.3 ft/s (1.0 m/s) |
V4208A90 |
-5°F to 400°F (-21°C to 204°C) |
< 3.3 ft/s (1.0 m/s) |
E4207A90 |
-65°F to 300°F (-54°C to 149°C) |
< 3.3 ft/s (1.0 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- SX959 Profile, Performance AN-Style Wiper with O.D. exclusion technology
Parker’s SX959 profile takes AN wipers to a new level by adding O.D. exclusion technology, while still
retrofitting MS-28776 (MS-33675) dash size grooves. SX959 wipers offer the same compact size
advantages as the SH959, while also improving contaminant exclusion in light to medium duty hydraulic
and pneumatic applications.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4615A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
P5065A88 |
-70°F to 200°F (-57°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- AH Profile, Premium Double-Lip Canned Wiper
Parker’s AH profile is the ultimate metal-clad excluder for heavy duty hydraulic applications. Press-fit
installation prevents O.D. contamination while the additional sealing lip works in conjunction with Parker
rod seals to provide redundant sealing for leakage reduction. An aggressive wiping lip, facing the
environment, ensures the utmost performance in contaminant exclusion along the rod. IMPORTANT: When using the AH wiper in conjunction with other rod seals, it is important to
select a rod seal profile that enables pressure relief of fluid into the system, otherwise a pressure
trap may form between the wiper and rod seal. Suggested rod profiles are the BT, BS, and B3 u-cups.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4300A90 |
-65°F to 275°F (-54°C to 135°C) |
< 1.6 ft/s (0.5 m/s) |
P4700A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
P4615A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- J Profile, Performance Canned Wiper
The press-fit installation of Parker’s J wiper guards against O.D. contamination and results in simple
counter-bore groove machining. The wiping lip on the J wiper is very aggressive, eliminating the
ingression of dust, mud and moisture from harsh work areas. J wipers are ideal for medium and heavy
duty hydraulic cylinders in the most demanding applications.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4300A90 |
-65°F to 275°F (-54°C to 135°C) |
< 1.6 ft/s (0.5 m/s) |
P4700A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
P4615A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- AY Profile, Premium Double-Lipped Wiper
The AY profile can be used as a heavy to light duty wiper. When used in high pressure applications in
conjunction with the proper Parker rod seals, the AY compliments the sealing system by providing an
additional beveled sealing lip, yielding excellent film-breaking and the driest rod sealing available. These
dual acting features also enable it to be used by itself in low pressure applications as both the rod seal
and the wiper. Knife-trimmed sealing lips ensure the best possible film breaking.
IMPORTANT: When using the AY wiper in conjunction with other rod seals, it is important to
select a rod seal profile that enables pressure relief of fluid into the system, otherwise a pressure
trap may form between the wiper and rod seal. Suggested rod profiles are the BT, BS, and B3 ucups.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4300A90 |
-65°F to 275°F (-54°C to 135°C) |
< 1.6 ft/s (0.5 m/s) |
P4301A90 |
-35°F to 225°F (-37°C to 107°C) |
< 1.6 ft/s (0.5 m/s) |
P4700A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- H and 8600 Profiles, Performance Double-Lip Wiper
Parker’s H and 8600 style wipers are double-lip excluders sharing identical geometries for combining the
actions of rod sealing and wiping. H wipers, available in plastic compounds, are intended for medium
pressure hydraulic applications as a redundant rod seal or for low pressure systems as the sole rod seal
and wiper. 8600 wipers, available in rubber compounds, are typically used for pneumatic cylinders where
lower friction is required. As with the H wiper, the 8600 can be used in tandem with another rod seal or by
itself as a dual-acting sealing/wiping unit.
IMPORTANT: When using H and 8600 wipers in conjunction with other rod seals, it is important to
select a rod seal profile that enables pressure relief of fluid into the system, otherwise a pressure
trap may form between the wiper and rod seal. Suggested rod profiles are the BT, BS, B3, 8400,
8500 and E5 u-cups.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4615A90 (H) |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
P5065A88 (H) |
-70°F to 200°F (-57°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
N4181A80 (8600) |
-40°F to 250°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- K Profile, Industrial Snap-In Wiper
K wipers offer a unique, light-load contact lip on both the sealing and wiping lips, making these excluders
suitable for light duty industrial hydraulic applications. They are most commonly used in conjunction with
Parker rod seals to provide a redundant film-breaking lip.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
P4615A90 |
-65°F to 200°F (-54°C to 93°C) |
< 1.6 ft/s (0.5 m/s) |
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- AD Profile, PTFE Wiper Seal
The Parker AD profile is a double acting wiper for use in low to medium duty hydraulic cylinders. It is a
two piece design comprised of a filled PTFE cap that is energized by a standard size o-ring. The
wiper and seal design of the AD profile assists the primary rod seal in preventing leakage by helping seal
fluid in the cylinder when the rod extends. When the cylinder rod retracts, the outside sealing edge
prevents contamination from entering the system. Parker’s AD profile will retrofit non-Parker wipers of
similar design. The AD profile may be ordered without the energizer.
Technical Data
Standard Materials* |
Temperature Range |
Surface Speed |
Cap |
040140% bronze-filled PTFE |
-200°F to 575°F (-129°C to 302°C) |
< 5 ft/s (1.5 m/s) |
Energizer |
A 70ANitrile |
-30°F to 250°F (-34°C to 121°C) |
|
* Alternate Materials: For applications that may require an alternate material, please consult Industrial Seal Inc.
- SG Profile, Metal Scraper
Parker is pleased to offer SG profile metal scrapers as a means to remove the toughest, most abrasive
contaminants that may adhere to cylinder rods, including ice, adhesives, coatings, tape and other
potentially damaging materials. By using rubber energizing elements behind the dual-contact scrapers,
SG provides the best possible removal of stubborn contaminants.
Technical Data
Standard Materials |
Energizer |
Scraper Ring |
Temperature Range |
N6017 |
Commercial Nitrile |
Bronze |
-40°F to 250°F (-40°C to 121°C) |
V6083 |
Commercial FKM |
Bronze |
-5°F to 400°F (-21°C to 204°C) |
4683 |
Commercial PTFE |
Bronze |
Cryogenic to 400°F (204°C) |
|